Engineering Manual Engineer Menu 1-4
43
Step 4 – Select Ward, Zone, User or Group Number
If appropriate, select the ward, zone, user or output group the output should follow.
Step 5 – Select Event to Activate Output
If you have chosen the output to follow a ward, zone or the system, you need to select the
event that should activate the output.
System Events
The following events are applicable if you have chosen the output to follow the system:
000 – Bell (SAB)
Activates when the control panel bell output is on, and deactivates when the control
panel bell output is off. The bell output may be activated on a confirmed or
unconfirmed alarm, depending on whether Bells on Confirm or Bells on Unconf is
selected (page 77).
001 – System Strobe
Activates when the control panel strobe output is on; deactivates when the control panel
strobe output is off.
002 – Switch 12 Volts
Activates when any ward is set; deactivates when any ward goes into alarm or its Entry
Delay timer (page 57) is running, or when all wards are unset. This output is normally used
as an input to latching detectors.
003 – Detector Reset
Deactivates for approximately 4 seconds when a user code is entered to set the first
ward. The output is used to reset latching detectors (smoke detectors, shock sensors,
etc.).
004 – Walk Test
Activates when a walk test is carried out (User option 1-1-2; see the Manager's Manual);
deactivates when the walk test is finished.
005 – Alarm
Activates when any ward has a full alarm (page 26); deactivates when all such wards
have been reset.
006 – Panic Alarm (PA)
Activates when any PA Silent or PA Audible zone (page 27) triggers, or if a user code of
type Panic Code is used. The output also activates if a user code of type Duress Code is
used while the system is being unset. The output deactivates when all such alarms have
been reset.
007 – Fire Alarm
Activates when any Fire zone (page 27) triggers. The Unset Fire attribute (page 38)
determines whether the output activates only when the zone is set, or when the zone is
either set or unset. The output deactivates when all Fire alarms have been reset.
008 – System Set
Activates when any ward is set; deactivates when all wards are unset.