Engineer Menu 1-4 Engineering Manual
44
009 – System Full Set
Activates when all defined wards are set; deactivates when any ward is unset.
010 – System Open
Activates when the system is unset; deactivates when any part of the system is set.
011 – Confirmed
Activates when there is a confirmed alarm (page 77), and remains active until the
system is reset.
012 – Courtesy Light
Activates for the duration of the Courtesy Time (page 60) when any ward has the Entry
Delay timer (page 57) running, or if any keypad is operated.
013 – Engineer On Site
Activates when the engineer’s code is entered; deactivates when the engineer is logged
off.
014 – Active Omit
If a latching sensor (such as a door contact or break glass, but NOT a PIR) activates a
zone, and the zone remains active until the end of the confirmation time (page 58), the
control panel omits the active zone and triggers the Active Omit output. The control
panel deactivates the output when a user resets the system.
015 – Zones Omitted
Activates when any zone is omitted (e.g. by user option 1-2); deactivates when all zones
have the omits removed.
016 – 24 Hour Omitted
Activates when any 24 Hour zone is manually omitted; deactivates when all omitted
zones are reinstated.
017 – 24 Hour Alarm
Activates when any 24 Hour zone (page 26) goes into the alarm state if the panel is
unset, and deactivates when all 24 Hour alarms have been reset.
018 – Zones Shunted
Activates when any shunt group (page 100) is omitted; deactivates when the shunt
group is reinstated.
019 – Technical
Activates when any Technical zone (see page 27) triggers; deactivates when the alarms
have been reset.
020 – PSTN Line Fault
Activates when a line fault is detected between the on-board modem and the Alarm
Receiving Centre (ARC); deactivates when the telephone line is restored. The Line Fault
communications option (page 98) must be enabled for this output to activate when
there is a line fault.
This option is not applicable to M550 and M750 systems.