Engineer Menu 1-9 Engineering Manual
74
05 – On-Line Enabled / On-Line Disabled
On-Line Enabled (default) – When using Downloader software, the On-Line Keypad
feature in the Downloader software is enabled.
On-Line Disabled When using Downloader software, the On-Line Keypad feature is
disabled.
06 – Unset Ward First / Set Ward First
Unset Ward First (default) – When the system is part set and a user code is entered, the
“0=Uset Wards” option is displayed first.
Set Ward First
– When the system is part set and a user code is entered, the “0=Set
Selection” option is displayed first.
07 – Digi Normal / Digi Inverted
Digi Normal (default) – The digital communicator outputs on the control panel switch
from +12V to 0V when active (+ve removed).
Digi Inverted
– The digital communicator outputs on the control panel switch from 0V to
+12V when active (+ve applied).
08 – Chime Audible / Chime Visible
Chime Audible (default) – Zones that have a Chime Tone attribute (page 31) will only
generate a chime tone.
Chime Visible
– Zones that have a Chime Tone attribute will generate a chime tone and
the keypads will display the zone that was triggered.
09 – Manual Omits / Automatic Omits
Manual Omits (default) – Zones that have the Omittable attribute (page 31) can be
omitted only from User option 1-2 (see the Manager's Manual).
Automatic Omits
– Zones with the Omittable attribute are automatically omitted if they
are active when the system is being set. This option is not relevant if the View Exit Errors
option is selected (page 76).
Do not use Automatic Omits if any partition is using a Deferred Set or Lock Set
(page 66), otherwise the system will not set.
10 – Omit Tampers No / Omit Tampers Yes
Omit Tampers No (default) – Omitting a zone using User option 1-2 (see the Manager's
Manual) will not also omit tamper faults from that zone.
Omit Tampers Yes – Omitting a zone using User option 1-2 also omits tamper faults from
that zone.
11 – Global Setting / Local Setting
Global Setting
(default)
– Allows users to set a partition from any keypad, providing their
user type allows this and the ward has been allocated to the user (as specified in User
option 2-4; see the Manager's Manual).
Local Setting – Allows a user to set a ward only if the ward has been allocated to the
user and the keypad belongs to that ward (page 35).