Engineer Menu 1-9 Engineering Manual
76
Access all codes
– Causes the outputs to activate when any user code is entered.
19 – NVM is Unlocked / NVM is Locked
NVM is Unlocked
(default)
– The panel can be reset to its factory defaults by shorting the
FACTORY RESTART pins on the control panel PCB during power-up.
NVM is Locked – The panel cannot be reset to its factory default settings by shorting the
FACTORY RESTART pins. Keypads give a warning sound if the terminals are shorted.
If you select this option, it is imperative that the engineer code is not forgotten. If it
is forgotten, the panel will need to be returned to Menvier Security for the system
to be returned to its factory default settings.
20 – Unshunt, no exit / Unshunt & exit
Unshunt, no exit (default) – Entering a Shunt user code (User option 2-4; see the
Manager's Manual) to reinstate zones does not start the exit procedure.
Unshunt & exit
– Entering a Shunt user code to reinstate zones starts the exit procedure.
21 – Ignore errors / View exit errors
Ignore errors
(default)
– When setting the system with one or more zones active (i.e.
triggered), the panel continues with the exit procedure, but displays the zones that are
currently active. If the zones are not cleared at the end of the exit procedure, the internal
sounder sounds, the external strobe flashes and the display shows an error.
View exit errors
– When setting the system with one or more zones active, the panel
displays the zones that are currently active and does not allow the system to be set while
zones are active. After clearing the active zones, the panel prompts for confirmation to
continue with the exit procedure.
22 – Mimic, All times / Mimic, Set only
Mimic, All times (default) – When using an output of type Mimic (page 55), the output
mimics the zone at all times.
Mimic, Set only – When using an output of type Mimic, the output mimics the zone only
if the zone is in a ward that is set. The output mimics the zone, even if the zone is omitted
or shunted (e.g. using User option 1-2 or 1-3; see the Manager's Manual).
23 – Lo Security Eng. / Hi Security Eng.
Lo Security Eng. (default) – You are able to access the Engineer menu options by
entering the engineer code.
Hi Security Eng. – When you enter the engineer code, a code is displayed. You need to
contact the Alarm Receiving Centre (ARC) and tell them the code to obtain a remote
reset code. Entering the remote reset code then gives access to the Engineer menu
options.
24 – Duress Allow NO / Duress Allow YES
Duress Allow NO
(default) – Prevents Duress and Panic user codes from being set up in
User option 2-4.
Duress Allow YES
– Enables Duress and Panic user codes to be set up in User option 2-4
(please refer to the Manager's Manual).
25 – Keypad PA OFF. / ON
Keypad PA OFF
(default)
– Switches off the keypad PA feature, as described next.