FC 300 Design Guide
How to Program
" 3-** Reference / Ramps
Par.
No. #
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
3-0* Reference limits
3-00 Reference range [0] Min - Max All set-ups TRUE - Uint8
3-03 Maximum reference 1500.000 Unit All set-ups TRUE -3 Int32
3-1* References
3-10 Preset reference 0.00 % All set-ups TRUE -2 Int16
3-12 Catch u p/slow down value 0.00 % All set-ups TRUE -2 Int16
3-13 Reference site [0] Linked to Hand / Auto All set-ups FALSE - Uint8
3-14 Preset relative reference 0.00 % All set-ups TRUE -2 Int32
3-15 Reference resource 1 [1] Analog input 53 All set-ups FALSE - Uint8
3-16 Reference resource 2 [2] Analog input 54 All set-ups FALSE - Uint8
3-17 Reference re source 3 [11] Local bus reference All set-ups FALSE - Uint8
3-18 Relative scaling reference resource [0] No function All set-ups FALSE - Uint8
3-19 Jog s peed 25 RPM All set-ups TRUE 67 U int16
3-4* Ramp 1
3-40 Ramp 1 type [0] Linear All set-ups TRUE - Uint8
3-41 Ramp 1 ramp up time Drive dependent All se t-ups TRUE -2 Uint32
3-42 Ramp 1 ramp down time Drive dependent All set-ups TRUE -2 Uint32
3-5* Ramp 2
3-50 Ramp 2 type [0] Linear All set-ups TRUE - Uint8
3-51 Ramp 2 ramp up time Drive dependent All se t-ups TRUE -2 Uint32
3-52 Ramp 2 ramp down time Drive dependent All set-ups TRUE -2 Uint32
3-6* Ramp 3
3-60 Ramp 3 type [0] Linear All set-ups TRUE - Uint8
3-61 Ramp 3 ramp up time Drive dependent All se t-ups TRUE -2 Uint32
3-62 Ramp 3 ramp down time Drive dependent All set-ups TRUE -2 Uint32
3-7* Ramp 4
3-70 Ramp 4 type [0] Linear All set-ups TRUE - Uint8
3-71 Ramp 4 ramp up time Drive dependent All se t-ups TRUE -2 Uint32
3-72 Ramp 4 ramp down time Drive dependent All set-ups TRUE -2 Uint32
3-8* Other ramps
3-80 Jog ramp time Drive dependent All set-ups TRUE -2 Uint32
3-81 Quick stop ramp time Drive dependent 1 set-up TRUE -2 Uint32
3-9* Digital Pot.Meter
3-90 Step Size 0.01 % All set-ups FALSE -2 Uint16
3-91 Ramp Time 1.00 s All set-ups FALSE -2 Uint32
3-92 Power Restore [0] Off All set-ups FALSE - U int8
3-93 Limit 100 % All set-ups FALSE 0 Uint16
*
default setting ()display text []value for use in communication via serial communication port
258
MG.33.B
6.22 - V LT is a registered Danfoss trademark

Table of Contents

Other manuals for Danfoss FC 300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss FC 300 and is the answer not in the manual?

Danfoss FC 300 Specifications

General IconGeneral
EnclosureIP20
ApprovalscUL, UL, CE
EMC filterBuilt-in
Communication OptionsCANopen, PROFIBUS DP
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Output Voltage0-100% of supply voltage

Related product manuals