FC 300 Design Guide
How to Program
" Parameters: Operation
and Display
" 0-0* Operation / Displ ay
Parameters related to the fundamental functions of
the adjustab le frequen cy drive, function of the LCP
buttons and configuration of the LCP display.
" 0-0* Basic Settings
Parameter group for basic frequency
converter settings.
0-01 Language
Option:
*
English UK (ENGLISH) [0]
German (DEUTSCH) [1]
French (FRANCAIS) [2]
Danish (DANSK) [3]
Spanish (ESPANOL) [4]
Italian (ITALIA NO) [5]
Chinese (CHINESE) [10]
Finnish (FINNISH) [20]
English US (ENGLISH US) [22]
Greek (GREEK) [27]
Portuguese (PORTUGUESE) [28]
Slovenian (SLOVENIAN) [36]
Korean (KOREAN) [39]
Japanese (JAPANESE) [40]
Turkish (TURKISH) [41]
Traditional Chinese [42]
Bulgarian [43]
Serbian [44]
Romanian (ROMANIAN) [45]
Hungarian (HUNGARIAN) [46]
Czech [47]
Polish (POLISH) [48]
Russian [49]
Thai [50]
Bahasa Indonesian (BAHASA
INDONESIAN) [51]
Function:
Defines the language to be used in display.
The adjustable frequency drive can be delivered
with 4 various language packages. English and
German are included in all packages. Eng lish
cannot be erased or manipulated.
Language package 1 consists of:
English, German, French, Danish, Spanish,
Italian and Finnish.
Language package 2 consists of:
English, German, Chinese, Korean, Japanese,
Thai and Bahasa Indonesian.
Language package 3 consists of:
English, German, Slovenian, Bulgarian, Serbian,
Romanian, Hungarian, Czech and Russian.
Language package 4 consists of:
English, German, Spanish, English U S, Greek,
Brazilian Portuguese, Turkis h and Polish.
0-02 Motor Speed U nit
Option:
*
RPM [0]
Hz [1]
Function:
Select dis play of motor speed pa rameters (i.e.
references, fee dbacks and limits) in terms of
shaft spe ed (RPM) or output freque n cy to the
motor (Hz). This parameter cannot be adjusted
while the motor is running.
0-03 Regional Settings
Option:
*
International [0]
US [1]
Function:
Select International [0] to set par.1-2 0 Motor Power
units to kW and the default value of par. 1-23Motor
Frequency to 50 Hz. Sel ect US [1 ] to set par. 1-21
Motor Power units to HP and the default value of
par. 1-23 Motor Frequency to 60 Hz. This parameter
cannot be adjusted while the motor is running.
0-04 Operating State at Power-up (Hand)
Option:
Resume [0]
*
Forced stop, use saved reference [1]
Forced stop, reference = 0 [2]
Function:
Select theoperating mode upon reconnection of the
frequency converter to mains
voltage after power
down in Hand (local) operation m o de.
*
default setting ()display text []value for use in communication via serial communication port
151
MG.33.B
6.22 - V LT is a registered Danfoss trademark