1.5 Functions of the AC Drive
Easy setup functions
Applications with preset parameters and I/O configuration for your process: Standard, HVAC, PID control, Multi-pump
Start-up wizards for fast and easy parameterization
Navigation functions
The [FUNCT] button for an easy change between the local and the remote control place (I/O or fieldbus)
A control page to operate and monitor of the most important values quickly
Advanced monitoring functions
Multimonitor
Trend curve
Fieldbus and I/O control
Motor control
Open loop control with frequency reference
Support for induction, permanent magnet, and synchronous reluctance motors
Identification run for setup of motor parameters
Flux and DC brake
Start and stop logic configuration
Reference selection and handling
8 preset frequencies
Motor potentiometer functions
A flush function
2 programmable ramp times
2 supervisions
3 ranges of prohibited frequencies
A forced stop
PID control
An external PID controller is available. Use it, for example, to control a valve with the I/O of the AC drive.
A sleep mode function that automatically enables and disables the operation of the drive to save energy
A 2-zone PID controller with 2 different feedback signals: minimum and maximum control
2 setpoint sources for the PID control. Selection to be made with a digital input.
A function for PID setpoint boost
A feedforward function to make the response to the process changes better
Pump control
A multi-pump control for the single drive and multidrive systems
The multimaster and multifollower modes in the multidrive system
A multi-pump system that uses a real time clock to autochange the pumps
Priming pump control, jockey pump control, pump impeller auto-cleaning, pump input pressure supervision, and frost pro-
tection function
Mechanical brake control
Timer functions and a real-time clock and (an optional battery is necessary)
Fire mode
Diagnostic and maintenance functions
Variety of configurable protection functions including user-defined faults
Supervision functions for frequency and motor variables and analog inputs
Motor overload protections
AB298035655957en-000201 / DPD0108312 | Danfoss A/S © 2023.08
Introduction
VACON® 100 FLOW
Application Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VACON 100 FLOW Series and is the answer not in the manual?

Danfoss VACON 100 FLOW Series Specifications

General IconGeneral
BrandDanfoss
ModelVACON 100 FLOW Series
CategoryDC Drives
LanguageEnglish

Related product manuals