Table 85: Multi-setpoint Parameters
Index
Parameter
Min
Max
Unit
Default
ID
Description
P3.13.12.1
Multi-Setpoint0
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15560
P3.13.12.2
Multi-Setpoint1
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15561
P3.13.12.3
Multi-Setpoint2
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15562
P3.13.12.4
Multi-Setpoint3
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15563
P3.13.12.5
Multi-Setpoint4
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15564
P3.13.12.6
Multi-Setpoint5
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15565
P3.13.12.7
Multi-Setpoint6
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15566
P3.13.12.8
Multi-Setpoint7
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15567
P3.13.12.9
Multi-Setpoint8
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15568
P3.13.12.10
Multi-Setpoint9
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15569
P3.13.12.11
Multi-Setpoint10
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15570
P3.13.12.12
Multi-Setpoint11
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15571
P3.13.12.13
Multi-Setpoint12
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15572
P3.13.12.14
Multi-Setpoint13
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15573
P3.13.12.15
Multi-Setpoint14
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15574
P3.13.12.16
Multi-Setpoint15
P3.13.1.5
P3.13.1.6
P3.13.1.4
0.0
15575
P3.13.12.17
Multi-SetpointSelection 0
DigINSlot0.1
15576
P3.13.12.18
Multi-SetpointSelection 1
DigINSlot0.1
15577
6.14 Group 3.14: External PID Controller
Table 86: Basic Settings for the External PID Controller
Index
Parameter
Min
Max
Unit
Default
ID
Description
P3.14.1.1
Enable External PID
0
1
0
1630
0 = Disabled
1 = Enabled
P3.14.1.2
Start Signal
DigIN Slot0.2
1049
OPEN = PID2 in stop mode
CLOSED = PID2 regulating
P3.14.1.3
Output in Stop
0.0
100.0
%
0.0
1100
P3.14.1.4
PID Gain
0.00
1000.00
%
100.00
1631
See P3.13.1.1
P3.14.1.5
PID Integration Time
0.00
600.00
s
1.00
1632
See P3.13.1.2
P3.14.1.6
PID Derivation Time
0.00
100.00
s
0.00
1633
See P3.13.1.3
P3.14.1.7
Process Unit Selection
0
37
0
1635
See P3.13.1.4
AB298035655957en-000201 / DPD01083120 | Danfoss A/S © 2023.08
Parameters Menu
VACON® 100 FLOW
Application Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VACON 100 FLOW Series and is the answer not in the manual?

Danfoss VACON 100 FLOW Series Specifications

General IconGeneral
BrandDanfoss
ModelVACON 100 FLOW Series
CategoryDC Drives
LanguageEnglish

Related product manuals