10.13.1.8 (ID 3608) Baseline Data Element 8
Location in the menu: V2.16.1.8
This monitoring value shows the baseline data. The baseline data is selected using the baseline data selector.
10.13.1.9 (ID 3609) Baseline Data Element 9
Location in the menu: V2.16.1.9
This monitoring value shows the baseline data. The baseline data is selected using the baseline data selector.
10.13.1.10 (ID 3610) Baseline Data Element 10
Location in the menu: V2.16.1.10
This monitoring value shows the baseline data. The baseline data is selected using the baseline data selector.
10.13.1.11 (ID 3622) Baseline Run Status
Location in the menu: V2.16.1.11
This monitoring value shows the baseline run status.
10.13.2 Stator Winding Monitor
10.13.2.1 (ID 3617) Current Unbalance
Location in the menu: V2.16.2.1
This monitoring value shows the current unbalance when condition-based monitoring is activated.
10.13.2.2 (ID 3620) Current Unbalance Threshold Value
Location in the menu: V2.16.2.2
This monitoring value shows the threshold value after interpolating.
10.13.2.3 (ID 3611) Current Warning S1 High Threshold
Location in the menu: V2.16.2.3
This monitoring value shows the warning S1 high threshold value.
10.13.2.4 (ID 3612) Current Warning S2 High Threshold
Location in the menu: V2.16.2.4
This monitoring value shows the warning S2 high threshold value.
10.13.2.5 (ID 3613) Current Alarm High Threshold
Location in the menu: V2.16.2.5
This monitoring value shows the alarm/fault high threshold value.
10.13.3 Vibration
10.13.3.1 (ID 3623) Vibration
Location in the menu: V2.16.3.1
This monitoring value shows the vibration when condition-based monitoring is activated.
10.13.3.2 (ID 3624) Vibration Threshold Value
Location in the menu: V2.16.3.2
This monitoring value shows the threshold value after interpolating.
10.13.3.3 (ID 3625) Vibration S1 High Threshold
Location in the menu: V2.16.3.3
This monitoring value shows the warning S1 high threshold value.
AB298035655957en-000201 / DPD01083164 | Danfoss A/S © 2023.08
Monitoring Value Descriptions
VACON® 100 FLOW
Application Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VACON 100 FLOW Series and is the answer not in the manual?

Danfoss VACON 100 FLOW Series Specifications

General IconGeneral
BrandDanfoss
ModelVACON 100 FLOW Series
CategoryDC Drives
LanguageEnglish

Related product manuals