Chapter 4 Parameters|
||
|
4-98 Revision 2016/03, 6ELE, V1.14
Parameter
Function Setting
Factory
Setting
End
user’s
master
End
user’s
slave
Note
10.24
Offset Level of
Liquid Leakage
0 to 50% 0 33 33
For
example:
Liquid
Leaks:
When the
motor drive
reaches its
balanced
status, its
feedback
level doesn't
exceed
0.12Kg for
every 2
seconds.
Then the
feedback
level will
descend at
this rate
until its
reaches the
target
feedback
level =
0.99kg
(3kg x 33%
= 0.00kg0.
Once the
feedback
level is
smaller than
0.99kg, the
motor drive
will start to
run.
Liquid leaks:
If the
feedback
level is more
than 0.12kg
per every 2
seconds
when the
motor drive
reaches its
balanced
status, the
motor drive
will start to
run right
away.
10.25
Liquid Leakage
Change Detection
0 to 100% (0: disable) 0 4 4
10.26
Time Setting for
Liquid Leakage
Change
0.1 to 10.0 sec (0: disable) 0.5 2 2