11.2.1.3 Standard values for fieldbus systems (optional)
Profibus:
Parameters Value
Profibus address 64
Table 38: Default values for Profibus
Profinet:
Parameters Value
IP address 10.10.24.10
Net mask 25.255.0.0
Gateway 10.10.20.9
Station name nic 50 repns
Table 39: Default values for Profinet
EtherNet/IP:
Parameters Value
IP address 10.10.24.11
Net mask 255.255.0.0
Gateway 10.10.20.9
DHCP inactive
BOOTP inactive
Table 40: Standard values EtherNet/IP
EtherCAT:
No settings are necessary.
11.2.2 MINIMAT–EC-Servo Screwdriver
The standard values for the MINIMAT–EC-Servo screwdriver can be set in the web-based
user interface in the system menu area Tool Settings. To do this, click on the button
"Standard Values".
Alternately, you can set the standard values in the display within the System menu area
Tool Settings. Switch to the screen "Set standard values" and press
.
Parameters Value
Offset gear available No
Gear ratio 1
Efficiency 100%
direction change No
Table 41: MINIMAT–EC-Servo Screwdriver Standard Values