15.2 Error in the Screwdriving Sequence
Number Displayed text Meaning Trouble shooting
0
OK
No error, the screwdriving
application was ended properly
-
1
Timeout
The set monitoring time of the
screwdriving sequence step has
been exceeded
2
Angle below target
The indicated minimum angle of
the screwdriving sequence step
was not achieved
3
Angle exceeded
The set maximum angle of the
screwdriving sequence step has
not been achieved
4
Torque not reached
The indicated minimum torque of
the screwdriving sequence step
was not achieved
5
Torque exceeded
The set maximum torque of the
screwdriving sequence step has
been exceeded
Check the screw process and
adapt the program if required.
6
Power unit: Invalid
program
An invalid program was
transmitted to the Power unit
Transfer the program over again.
7
To many E/A
commands
The program contains too many
I/O commands
Check the screwdriver program.
8
reserved - -
9
Invalid program
Program is not valid (does not
exist, or was created for another
screwdriver)
Check the program and adjust if
required or select a different
program.
10
Abort
The start signal has been reset
prior to the normal end of the
screwdriving application.
The start signal must be present
until the end of the screwdriver
operation.
11
Over current
Current exceeds maximum
permissible value
Check the screw assembly
process and adjust the program if
required.
If necessary please contact
DEPRAG Service.
12
Error during holding
torque
While holding the torque the
tension dropped below the target
torque before the end of the
sequence
Check the screw process and
adapt the program if required.
13
Power unit: Write error Error while writing the program Transfer the program over again.
14
Power unit not
initialized.
Power element not initialized with
screwdriver data.
recycle power to the cordless EC-
screwdriver.
15
Fault during position
hold
Fault during position hold, position
could not be loaded
16
Friction torque undercut
Friction torque in monitored
window too small
17
Friction torque
exceeded
Friction torque in monitored
window too large
Check the screw process and
adjust the program if required.
18
I²t - overload
Overload of the tool via a defined
time frame
Check the screw assembly
process and adjust the program if
required. If necessary please
contact DEPRAG Service.
19
Program number larger
than 100
The program number selected is
not supported
Enter a program number between
1 and 100.
20
General fault general fault
21
Power unit has
stopped
The screw connection was
terminated, because the power
unit has switched off.
Please contact the DEPRAG
Service Department.
22 General error general error -
Table 50: Sequence errors