78
Figure 67: Diagnosis I/O-Port, Program choice (Page 2)
All the inputs are located on the SPS1 (GX2) interface.
Designation Pin Description
Program selection 0 4
Program selection 1 5
Program selection 2 6
Program selection 3 7
Program selection 4 24
Program selection 5 25
Program selection 6 26
Choice of screwdriving program 1 - 120
Table 24: Diagnosis I/O-Port, Program choice (Page 2)
Press the key , to get to the next diagnosis page or , to go the previous diagnosis
page.
Figure 68: Diagnosis I/O-Port, Outputs (Page 3)
All the outputs are located on the SPS1 (GX2) interface. The Reload signal is located on
the I/O interface 3 (GX5).
Designation Pin Description
System OK (PU+MC) 11 Main controller and power unit have no faults
Ready 28 the AST40 is ready for screwdriving
Screwdriving cycle active 14 a screwdriver cycle is just active
OK 29 Status of the last sequence was OK