18 Glossary
Term Description
Clearance for start
If the clearance for start is activated then the screwdriver will only
start if there are 24V at the clearance to start input. Otherwise the
controller is not ready to screw.
Command General program step to create the screwdriving sequence (e.g.
setting the output).
EC screwdriver The screwdriver has a brushless electronic drive (EC motor,
abbreviation for electronic commutate).
EC servo screwdriver The screwdriver has a brushless electronic drive (EC motor,
abbreviation for electronic commutate) and has an integrated,
sensor controlled torque and angle of rotation measurement.
Encoder visual sensor to detect the current position of a motor shaft or a
drive unit
Ethernet Data network technology for local data networks to exchange data
between all devices connected in a network (computer, printer,
etc.).
EtherNet/IP Ethernet-based fieldbus for the control and data exchange with
sequence control resp. the base station, developed by the
company Allen-Bradley
EtherCAT Ethernet-based fieldbus for the control and data exchange with
sequence control resp. the base station, initiated by the company
Beckhoff
Final value dataset The dataset in which all result data for the screw assembly is
stored.
Handheld screwdriver Screwdriver to use at hand-work places
High Signal level +24V
Impact start The screwdriver starts as soon as the blade is pressed and makes
contact.
Lever start
The screwdriver starts as soon as a button or lever on the
screwdriver is actuated.
Low Signal level 0V
Mean value
Mean value on a certain amount of measuring values.
n
i
n
x
n
x
1
1
Main controller Component for processing the screwdriving programs
Monitoring criteria
Criteria that will lead to abort the screwdriving program even
though the switching off criteria has not yet been reached (e.g. time
monitoring, angle monitoring during torque screw assemblies).
MC see main controller
n.c. not connected – the named pin is not connected
NOK not error free