16
6.2.7.3 Interface SPS 2
Designation: GX3
Plug connector: SUB-D 25-pole (bushing)
Pin Designation Type Pin Designation Type
1 24V - 14 GND internal -
2 24V external - 15 GND external -
3 Not in use Input 16 n.c.
4 Sequence 5 Input
17 n.c.
5 Sequence 6 Input 18 Sequence 9 Input
6 Sequence 7 Input 19 Sequence 10 Input
7 Sequence 8 Input 20 Sequence 11 Input
8 Sequence 5 Output 21 Sequence 12 Input
9 Sequence 6 Output 22 Sequence 9 Output
10 Sequence 7 Output 23 Sequence 10 Output
11 Sequence 8 Output 24 Sequence 11 Output
12 n.c. 25 Sequence 12 Output
13 n.c.
Table 6: Configuration I/O interface SPS2
CAUTION
Maximum load per output of 50 mA. The total current for all the interfaces
must not exceed 600 mA.
6.2.7.4 Interface 3
Designation: GX4
Plug connector: SUB-D 15-pole (bushing)
Pin Designation Type Pin Designation Type
1 Not in use Input 9 Not in use Input
2 24V Out - 10 GND external -
3 24V Out - 11 GND external -
4 24V Out - 12 GND external -
5 Not in use Input 13 Not in use Output
6 Not in use Output 14 Reload Output
7 n.c. 15 GND external -
8 24V Out -
Table 7: Configuration I/O interface 3
CAUTION
Maximum load per output of 50 mA. The total current for all the interfaces
must not exceed 600 mA.
IMPORTANT
24V Out: 24 V DC power supply for the supply of external sensors.