F
Clean the inside of the coolant tank.
Pour a little tap water into the tank, and then shake the tank to the left and right. Dispose of any dirty water. Repeat
this step until the water does not become dirty when you shake the tank.
G
Install (two) new coolant lters.
Orient the coolant lters so that the end with the protrusion is at the front (the end where the coolant tank cap is
present).
Orient the protrusion at the front (the end
where the coolant tank cap is present).
CAUTION
Handle the coolant lter carefully.
Dropping the lter or grasping it too strongly may damage the lter. If the ltration function does not
work due to damage, the coolant line may be clogged with milling waste, which may lead to coolant
leaks and re and electrical shock due to current leakage.
H
Attach the drain cap to the coolant tank.