Frame descriptions Extended Modem Status frame - 0x98
Digi XBee® 3 Zigbee® RF Module 308
Status
code
Transparent
mode string Description Status data Description
0x06
Reject ID Not an association candidate because
configured pan ID does not match that given
in the beacon response.
0x07
Reject NJ
Not an association candidate because it is not
allowing joins.
0x08 panID Match
JV/NW with search option (DO80) has found a
matching network.
panId(2) 16 bit PAN Identifier for network
0x09
Reject
LQIRSSI
JV/NW with search option (DO80) candidate
rejected because this beacon response is
weaker than an earlier beacon response.
0x0A Beacon Saved This beacon response is a suitable candidate
for an association request.
radioChannel
(1)
channel number ranging from 11 to 26 (0x0B to 0x1A)
radioTxPower
(1)
low level signed byte value for transmit power, values range
from 0xC9 to 0x05 inclusive
panid(2) 16 bit PAN Identifier for network
extendedPanId
(8)
64 bit PAN Identifier for network
0x0B
AI AI value has changed.
AIStatusCode
(1)
See a description of AI (Association Indication)
0x0C Permit Join
NJ
setting (Permit Join Duration) has changed value(1)
See a description of the NJ (Node Join Time) command.
0x0D Scanning Active scanning has begun. ChannelMask
(4)
A 32 bit value driven by the SC setting where bit positions 11
through 26 show which channels are enabled for the
upcoming Active Scan. See a description of SC (Scan
Channels).
0x0E Scan Error An error occurred during active scan. StatusCode(1)