Programming
Operating Instructions 581 - 01.0 - 05/2016100
In the subitem Output test you can test the individual output
elements.
To perform an output test:
1. Select Ou
tput test.
2. Press the button.
3
. Using the arrow buttons, select the desired output element
(see following table).
Th
e current status is displayed:
0 = Output not activated
1 = Output activated
4. Press the button.
Th
e output is switched over.
Functions of the operating elements
Output Function
Y01 Needle thread cutter;
for 581-112 and 581-312 additional looper thread cutter
Y02 Looper thread tension
Y03 Fabric clamp
Y04 Spreader
Y05 Needle thread advancing device
Y06 Slitter
Y07 Slitter
Y08 Looper thread advancing device;
only on the 581-121 and 581-321
Y09 Needle thread catcher to the sewing material
Y10 Open the needle thread catcher
Y11 Needle thread catcher to the needle