Programming
Operating Instructions 581 - 01.0 - 05/2016 101
You can quit the output test using the button.
Input test
In the subitem Inp
ut test you can test the individual input
elements.
To perform an input test:
1. Select In
put test.
2. Press the button.
3
. Using the arrow buttons, select the desired input element
(see following table).
Th
e current status is displayed:
0 = Input not activated
1 = Input activated
Functions of the input elements
Y12 Looper thread cutter;
only on the 581-121, 581-141 and 581-321, 521-341
Y13 Multiflex blade
Y14 Multiflex cutting block
Y15
Slitter
Output Function
Input Function
S03 Cutting punch position
S04 Light barrier mode
S05 Light barrier mode
S09 Button 1
S10 Button 2