Troubleshooting
Operating Instructions 581 - 01.0 - 05/2016 163
1006 Sewing motor fault Max. speed exceeded
Sewing motor cable
de
fective
Sewing motor defective
Switch the machine off and
o
n again
Replace the encoder
Perform reset
Replace the sewing motor
Contact customer service
1007 Error in the reference
ru
n
Replace the encoder
Eliminate stiff movement in
th
e machine
1008 Sewing motor encoder
er
ror
Replace the encoder
1010 Sewing motor
syn
chronization error
External synchronizer plug
(Sub-D, 9-pin) not
connected
Connect plug of external
synchronizer to control, use
correct connection (Sync)
Replace the reference
switch or
synchronizer
Only required for machines
with transmission!
1011 Sewing motor
syn
chronization error
(Z pulse)
Switch off the control, use
handwheel to turn and
switch on the control again
If error is not corrected,
check encoder
1012 Sewing motor
syn
chronization error
Replace the synchronizer
1051 Sewing motor timeout Cable to sewing motor
reference switch defective
Reference switch defective
Replace the cable
Replace reference switch
(9
815 935006)
1052 Sewing motor
over
current
Sewing motor cable
defective
Sewing motor defective
Control defective
Replace the sewing motor
cable
Replace the sewing motor
Replace the control
Error Meaning Possible cause Remedial action