EasyManua.ls Logo

DURKOPP ADLER 581 - Page 165

DURKOPP ADLER 581
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Operating Instructions 581 - 01.0 - 05/2016 163
1006 Sewing motor fault • Max. speed exceeded
• Sewing motor cable
de
fective
• Sewing motor defective
• Switch the machine off and
o
n again
• Replace the encoder
• Perform reset
• Replace the sewing motor
• Contact customer service
1007 Error in the reference
ru
n
• Replace the encoder
• Eliminate stiff movement in
th
e machine
1008 Sewing motor encoder
er
ror
• Replace the encoder
1010 Sewing motor
syn
chronization error
• External synchronizer plug
(Sub-D, 9-pin) not
connected
• Connect plug of external
synchronizer to control, use
correct connection (Sync)
• Replace the reference
switch or
synchronizer
• Only required for machines
with transmission!
1011 Sewing motor
syn
chronization error
(Z pulse)
• Switch off the control, use
handwheel to turn and
switch on the control again
• If error is not corrected,
check encoder
1012 Sewing motor
syn
chronization error
• Replace the synchronizer
1051 Sewing motor timeout • Cable to sewing motor
reference switch defective
• Reference switch defective
• Replace the cable
• Replace reference switch
(9
815 935006)
1052 Sewing motor
over
current
• Sewing motor cable
defective
• Sewing motor defective
• Control defective
• Replace the sewing motor
cable
• Replace the sewing motor
• Replace the control
Error Meaning Possible cause Remedial action

Table of Contents