EasyManua.ls Logo

DURKOPP ADLER 581 - Page 166

DURKOPP ADLER 581
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Operating Instructions 581 - 01.0 - 05/2016164
1053 Line voltage too high Line voltage too high Check the line voltage
1054 Internal short circuit Replace the control
1055 Sewing motor overload Sewing motor is sluggish or
is bl
ocked
Sewing motor defective
Control defective
Eliminate sluggishness/
blockage
Replace the sewing motor
Replace the control
1056 Sewing motor
over
temperature
Sewing motor not moving
freely
Sewing motor defective
Control defective
Eliminate sluggishness
Replace the sewing motor
Replace the control
1058 Sewing motor speed
is greater than the
se
tpoint
Reference switch defective
Sewing motor defective
Replace reference switch
(9
815 935006)
Replace the sewing motor
1060 PowerParts Replace the control
1062
Sewing motor IDMA
auto-increment
•Disturbance Switch the machine off and
on again
1120 Software error Parameter not initialized Perform software update
1203 Sewing motor:
Position not reached
Switch the machine off and
o
n again
Perform software update
Contact Customer Service
1302 Sewing motor current
fee
d fault
Sewing motor blocked
Encoder cable not
con
nected or defective
Encoder defective
Remove the blockage
Check the encoder cable
an
d replace, if necessary
Replace the sewing motor
1330 Sewing motor not
re
sponding
Switch the machine off and
on again
Perform software update
Contact Customer Service
Error Meaning Possible cause Remedial action