Troubleshooting
Operating Instructions 581 - 01.0 - 05/2016164
1053 Line voltage too high • Line voltage too high • Check the line voltage
1054 Internal short circuit • Replace the control
1055 Sewing motor overload • Sewing motor is sluggish or
is bl
ocked
• Sewing motor defective
• Control defective
• Eliminate sluggishness/
blockage
• Replace the sewing motor
• Replace the control
1056 Sewing motor
over
temperature
• Sewing motor not moving
freely
• Sewing motor defective
• Control defective
• Eliminate sluggishness
• Replace the sewing motor
• Replace the control
1058 Sewing motor speed
is greater than the
se
tpoint
• Reference switch defective
• Sewing motor defective
• Replace reference switch
(9
815 935006)
• Replace the sewing motor
1060 PowerParts • Replace the control
1062
Sewing motor IDMA
auto-increment
•Disturbance • Switch the machine off and
on again
1120 Software error • Parameter not initialized • Perform software update
1203 Sewing motor:
Position not reached
• Switch the machine off and
o
n again
• Perform software update
• Contact Customer Service
1302 Sewing motor current
fee
d fault
• Sewing motor blocked
• Encoder cable not
con
nected or defective
• Encoder defective
• Remove the blockage
• Check the encoder cable
an
d replace, if necessary
• Replace the sewing motor
1330 Sewing motor not
re
sponding
• Switch the machine off and
on again
• Perform software update
• Contact Customer Service
Error Meaning Possible cause Remedial action