Operating Instructions 581 - 01.0 - 05/2016166
1431 Sewing motor:
Stop position
Internal sewing motor fault Reduce the positioning
speed
Perform software update
1450 Internal sewing motor
fau
lt
Internal sewing motor fault Switch the machine off and
on again
Perform software update
Replace the control
Contact Customer Service
1498
1499
Internal sewing motor
fau
lt
Internal sewing motor fault Switch the machine off and
on again
Perform software update
Replace the control
Contact Customer Service
21 .. .. Stepper motor X-axis
22 .. .. Y-axis stepper motor
23 .. .. Z-axis stepper motor
.. .. 02 Stepper motor current
fee
d fault
Stepper motor not moving
freely or blocked
Encoder cable not
con
nected or defective
Stepper motor cable is not
co
nnected or is faulty
Encoder defective
Stepper motor defective
Eliminate sluggishness/
blockage
Check the encoder cable
an
d replace, if necessary
Replace the encoder
If the stepper motor is not
supplied with current:
Check the stepper motor
cab
le and replace, if
necessary
Replace the stepper motor
.. .. 03 Stepper motor step
l
osses
Stiff mechanical movement
or blockage
Eliminate mechanical
sluggishness or blockage
.. .. 21 Encoder plug (Sub-D, 9-pin)
no
t connected or defective
Encoder defective
Check the connection of the
encoder cable and replace, if
necessary
Error Meaning Possible cause Remedial action