SHANGHAI ESURVEY GNSS CO., LTD.
40
3. Input a name for the new point and press F4 REC for record. The display shows
Data Saved and automatically returns to BEARING-DISTANCE display.
5.2.4.4.2.3 Set Distance-distance
The principle is as follows:
To set distance-distance, do the following:
1. In INTERSECTIONS display, press F3 / 3.
2. Input data, and press F2 CALC for computing. DISTANCE-DISTANCE display
shows:
3. Input a name for the new point and press F4 REC for record. The display shows
Data Saved and automatically returns to DISTANCE-DISTANCE display.