Section 5847 User Instructions
Issue AL, July 24, 2006 Spec. Nos. 586505000 and 5865055000 (Model LMS1000)
Page 3-18 Chapter 3. Commands
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
TL1 Commands Supported Description
RELEASE-EXTERNAL-CONTROL
RLS-EXT-CONT
Instructs the system to de-activate a specified relay channel to
release an external control.
RETRIEVE-ALARM
RTRV-ALM-{EQPT|ALL}
Instructs the system to send the current state of its alarm
conditions associated with one or more equipment units,
facilities, etc. within the system.
RETRIEVE-ALARM-ENVIRONMENT
RTRV-ALM-ENV
Instructs the system to send the current state of its alarm
conditions associated with the system's environment.
RETRIEVE-ATTRIBUTE
RTRV-ATTR-{EQPT|ALL}
Instructs the system to send the current notification code
associated with the specified events.
RETRIEVE-ATTRIBUTE-ENVIRONMENT
RTRV-ATTR-ENV
Instructs the system to send the current attributes associated
with the specified environmental alarm.
RETRIEVE-CONDITION
RTRV-COND-{EQPT|ALL}
Instructs the system to send the current state and standing
condition (alarm or status) associated with one or more
equipment units, facilities, etc. within the system.
RETRIEVE-EXTERNAL-CONTROL
RTRV-EXT-CONT
Instructs the system to retrieve the state of the specified relay
channels controlling external controls.
RETRIEVE-HEADER
RTRV-HDR
Requests that the system reply with a "normal" response
indicating COMPLD.
RETRIEVE-LOG
RTRV-LOG
Instructs the system to retrieve the contents of an existing log.
RETRIEVE-PERFORMANCE MONITORING
RTRV-PM-{EQPT|ALL}
Instructs the system to send its current set of Performance
Monitoring (PM) data associated with one or more equipment
units, facilities, etc. within the system.
RETRIEVE-THRESHOLD
RTRV-TH-{EQPT|ALL}
Instructs the system to send the current threshold level (alarm
limits) of one or more monitored parameters for which violation
will trigger an automatic message.
RETRIEVE-USER-SECURITY
RTRV-USER-SECU
Retrieves a user’s security parameters. The calling identifier
(<cid>) parameter (i.e., user primary phone number), and user
access privilege (<uap>) parameter (i.e., user access level) of
the specified user is retrieved.
SET-ATTRIBUTE
SET-ATTR-{EQPT}
Instructs the system to set the current notification code
associated with the specified events.
SET-ATTRIBUTE-ENVIRONMENT
SET-ATTR-ENV
Instructs the system to set the current attributes associated
with the specified environmental alarm.
SET-SYSTEM_IDENTIFICATION
SET-SID
Instructs the system to change its system identifier (SID)
parameter to a given value.
SET-THRESHOLD
SET-TH-{EQPT}
Instructs the system to set threshold levels (alarm limits) for a
monitored parameter that, when exceeded, will trigger an
automatic message.