User Instructions Section 5847
Spec. Nos. 586505000 and 5865055000 (Model LMS1000) Issue AL, July 24, 2006
Chapter 3. Commands Page 3-215
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
SET MODE
Description: This command is only available if the TL1 software option is installed in the
system. Configures TL1 port operation.
Command Level: 6
Syntax: SET MODE
SE MO
Comments: When this command is entered, the current values of the TL1 port are
displayed, followed by prompts to enter new values. Type a new value, or press ENTER
to keep the current value.
Available TL1 configuration parameters:
Enter new TL1/X.25 port data rate: (TL1/X.25 option parameter only.) Enter the
data rate in bits/sec for the TL1/X.25 port (either 110, 300, 1200, 2400, 4800, or
9600). The default is 9600 bits/sec. If the X28 Mode is selected, the data rate is
determined automatically. The PAD device must be connected for this to be
accomplished.
Enter new TL1 port number: (TL1 [over Ethernet] option parameter only.) Enter
2020 as the Telnet port number.
TCP Keepalive (Y or N): (TL1 [over Ethernet] option parameter only.) Enter "Y"
if the system should test TL1 Telnet connection to remote system (recommended),
and "N" if not.
Session Timeout (0-1440, 0=disabled): Enter the TL1 port session timeout value in
minutes (0-1440, 0=disabled). A value of zero disables the session timeout feature.
Auto logon (Y or N): Enter "Y" if the system is required to automatically establish a
user session, and "N" if not.
Auto logon user: This attribute only appears if "Y" is selected for "AUTO LOGON".
Enter the number of the user who is automatically logged on by the system. The
configuration of the entered user determines the access level of the user session and
is used in determining when a report must be sent.
AID Delimiter (Y or N): In LMS1000, the TL1 Access Identifier (AID) parameter
consists of an LMS1000 Access Identifier parameter and an LMS1000 Sub-Access
Identifier parameter, as explained under LMS1000 Command SET AID. Enter "Y" to
enable the use of a hyphen (AID delimiter) between the LMS1000 Access Identifier
parameter and LMS1000 Sub-Access Identifier parameter in all responses to TL1
commands and reports containing a TL1 Access Identifier field. Enter "N" to disable
the use of the "AID delimiter".
Save changes (Y or N): Enter a "Y" if the above changes are to be saved in the TL1
port configuration, and "N" if not. If "Y" is entered, the following message appears
"Must issue a hardware reset for changes to take effect."
Notes: This command can only be executed through the local port.