Section 5847 User Instructions
Issue AL, July 24, 2006 Spec. Nos. 586505000 and 5865055000 (Model LMS1000)
Page 3-328 Chapter 3. Commands
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
INITIALIZE-REGISTER
(INIT-REG-{EQPT|ALL})
Referenced In: TR-NWT-000833, Issue 5; pg. 4-139
General Description: Instructs LMS1000 to initialize to a specific value one or more
storage registers or event counters associated with one or more equipment units,
facilities, etc. within LMS1000.
In most common instances, these registers contain performance monitoring information.
An entry is made in the LMS1000’s event log indicating this command was executed by
the current sessions user. The event description indicates that the statistics were
cleared.
Related Commands: None
LMS1000 Access Level: 6
An error response with the error code PICC is returned if this command is entered by a
valid user whose level of access is less than the access level of this command.
LMS1000 Equivalent: CLR STATS <t<n>>
LMS1000 Input Format Variations: The command code modifier COM is not supported
by LMS1000.
<aid>
Specifying a value of ALL for the access identifier (<aid>) parameter initializes all
registers for all access identifiers of the type defined by the command code modifier. If
the command code modifier is ALL, the value of the access identifier parameter must be
ALL. A NULL value is not permitted for this parameter. Invalid values received for this
parameter return an error response with the error code IIAC.
<montype>
This parameter is not supported by LMS1000. The only valid value for this parameter is
ALL. Invalid values received for this parameter return an error response with the error
code IDNV.
<monval>
This parameter is not supported by LMS1000. The only valid value for this parameter is
NULL. Invalid values received for this parameter return an error response with the error
code IDNV.
<locn>
This parameter does not apply to LMS1000. The only valid value for this parameter is
NULL. Invalid values received for this parameter return an error response with the error
code IDNV.
<dirn>

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson LMS1000 and is the answer not in the manual?

Emerson LMS1000 Specifications

General IconGeneral
BrandEmerson
ModelLMS1000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals