User Instructions Section 5847
Spec. Nos. 586505000 and 5865055000 (Model LMS1000) Issue AL, July 24, 2006
Chapter 3. Commands Page 3-325
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
NAME attribute for this user’s LMS1000 user configuration. If the access identifier
parameter matches the NAME attribute of an inactive LMS1000 user, that user is
activated. If the access identifier parameter does not match the NAME attribute of an
inactive LMS1000 user, the first inactive LMS1000 user is activated. The NAME attribute
for this user is changed to that specified by this value. If there are no inactive LMS1000
users remaining, then an error response is returned with the error code SROF. If the
user being activated is already active, then an error response is returned using the error
code PIUI. Other invalid values return an error response with the error code IIAC.
<pid>
The privilege identifier (<pid>) parameter determines the new privilege identifier which
replaces the current one. This parameter is the new PASSWORD attribute for the
specified user’s LMS1000 user configuration. The LMS1000 allows a maximum of eight
characters for a password. At least two characters must be non-alpha, and at least one
character must be a symbol. (Valid symbols are the ‘#’, ‘%’, and ‘+’ characters.) Invalid
values received for this parameter return an error response with the error code IDNV. If
the entered value for this parameter matches an existing privilege identifier for another
user, an error response with the error code PIUI is returned.
<cid>
The calling identifier (<cid>) parameter determines the new calling identifier which
replaces the current one. This parameter is the new PRIMARY PHONE attribute for the
specified user’s LMS1000 user configuration. It can either be the network address or the
phone number of the specified user. Invalid values received for this parameter return an
error response with the error code IDNV.
<uap>
The user access privilege (<uap>) parameter determines the new user access privilege
which replaces the current one. This parameter is the new ACCESS LEVEL attribute for
the specified user’s LMS1000 user configuration. Invalid values received for this
parameter return an error response with the error code PIUC.
<keyword-defined block>
This parameter has no relevance in LMS1000, and is ignored if included.
LMS1000 Response Format Variations: None