Setup & Operation 5. Memory Port
RC620 Rev.8 37
5.2.2 Adoptable USB Memory
Use USB memory that meets the following conditions.
- USB2.0, USB1.1 supported
- Without security function
USB memory with password input function cannot be used.
- No installation of a driver or software is necessary for Windows.
- Without encryption protection or security software.
Note that the conditions above are no guarantee of your USB memory availability with the
Controller.
The Controller cannot recognize some types of the USB memory.
5.3 Controller Status Storage Function
5.3.1 Controller Status Storage with Trigger Button
Use this procedure to save the status of the Controller to USB memory.
(1) Insert the USB memory into the memory port.
(2) Wait approximately 10 seconds for USB memory recognition.
(3) Press the trigger button on the Controller.
The LCD displays the following repeatedly during the data transfer.
Wait for the display to turn back to the normal. (Data transfer time depends on the project
size, etc..)
(4) When the storage has been completed, LCD displays as below for two seconds.
When the storage has failed, LCD displays as below for two seconds.
(5) Remove the USB memory from the Controller.
- USB memory with LED is recommended to check the status changes in procedure (2).
- When storage is executed during Motor ON status, it may fail to store the status. Use
another USB memory or execute the storage during Motor OFF status.