English
FI8
TERMINAL
SIGNAL
TYPE
DESCRIPTION
ACTION
1
24 VDC
-
Power supply 24 VDC
-
2
NODE_SEL0
Input
Node selection
Input ("type B" as per EN 61131-2)
3
NODE_SEL1
Input
Input ("type B" as per EN 61131-2)
4
GND
-
Power supply 0 VDC
-
5
INPUT1
Input
Digital input 1
Input as per EN 61131-2
6
INPUT2
Input
Digital input 2
Input as per EN 61131-2
7
INPUT3
Input
Digital input 3
Input as per EN 61131-2
8
INPUT4
Input
Digital input 4
Input as per EN 61131-2
9
OUT_TEST1
Output
Output for short circuit detection
PNP active high
10
OUT_TEST2
Output
Output for short circuit detection
PNP active high
11
OUT_TEST3
Output
Output for short circuit detection
PNP active high
12
OUT_TEST4
Output
Output for short circuit detection
PNP active high
13
INPUT5
Input
Digital input 5
Input as per EN 61131-2
14
INPUT6
Input
Digital input 6
Input as per EN 61131-2
15
INPUT7
Input
Digital input 7
Input as per EN 61131-2
16
INPUT8
Input
Digital input 8
Input as per EN 61131-2
Table 3
FM4
TERMINAL
SIGNAL
TYPE
DESCRIPTION
ACTION
1
24 VDC
-
Power supply 24 VDC
-
2
NODE_SEL0
Input
Node selection
Input ("type B" as per EN 61131-2)
3
NODE_SEL1
Input
Input ("type B" as per EN 61131-2)
4
GND
-
Power supply 0 VDC
-
5
INPUT1
Input
Digital input 1
Input as per EN 61131-2
6
INPUT2
Input
Digital input 2
Input as per EN 61131-2
7
INPUT3
Input
Digital input 3
Input as per EN 61131-2
8
INPUT4
Input
Digital input 4
Input as per EN 61131-2
9
OUT_TEST1
Output
Output for short circuit detection
PNP active high
10
OUT_TEST2
Output
Output for short circuit detection
PNP active high
11
OUT_TEST3
Output
Output for short circuit detection
PNP active high
12
OUT_TEST4
Output
Output for short circuit detection
PNP active high
13
INPUT5
Input
Digital input 5
Input as per EN 61131-2
14
INPUT6
Input
Digital input 6
Input as per EN 61131-2
15
INPUT7
Input
Digital input 7
Input as per EN 61131-2
16
INPUT8
Input
Digital input 8
Input as per EN 61131-2
17
OUT_TEST5
Output
Output for short circuit detection
PNP active high
18
OUT_TEST6
Output
Output for short circuit detection
PNP active high
19
OUT_TEST7
Output
Output for short circuit detection
PNP active high
20
OUT_TEST8
Output
Output for short circuit detection
PNP active high
21
INPUT9
Input
Digital input 9
Input as per EN 61131-2
22
INPUT10
Input
Digital input 10
Input as per EN 61131-2
23
INPUT11
Input
Digital input 11
Input as per EN 61131-2
24
INPUT12
Input
Digital input 12
Input as per EN 61131-2
Table 4