Model
AZ-FO4
AZ-FO4O8
PFH
d
(EN IEC 61508:2010)
2.9 E-9
2.94 E-9
Rated voltage
24 VDC ± 20 %
Power dissipation max.
3 W max.
Switching voltage
240 VAC
Switching current
6 A max.
Normally open contacts
4
INPUT FBK/RESTART (no./description)
4/EDM control/automatic or manual operation possible using
RESTART pushbutton
Digital OUTPUT (no./description)
-
8/Programmable output
PNP active high
Response time
12 ms
Mechanical life contacts
> 40 x 10
6
Connection
Terminal blocks
Connection to MSC-CB
Via proprietary 5-way bus MSCB from EUCHNER

Table of Contents