EUCHNER MSC - 8.4.2. Module FI8 FO2 (Figure 28)

EUCHNER MSC
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English
AZ-FO4 (Figure 25)
SIGNIFICANCE
LED
RECTIFICATION
MEASURE
RUN
IN FAIL
EXT FAIL
SEL0/1
RELAY1/4
CLEAR1/4
GREEN
RED
RED
ORANGE
RED
GREEN
YELLOW
Internal fault
OFF
Flashes 2/3
times
OFF
Indicates the
physical address
of the module
Red
OFF
Send module to
EUCHNER for repair
Compatibility error
OFF
Flashes 5
times
OFF
Flashes 5 times
Flashes 5
times
Firmware version not
compatible with MSC-
CB. Send to EUCHNER
for firmware upgrade.
Relay output error
OFF
Flashes 4
times
OFF
Flashes 4 times
(only the LED corre-
sponding to the output
in the ERROR mode)
OFF
If the problem persists,
send module to
EUCHNER for repair.
Error during commu-
nication with base
unit
OFF
Flashes 5
times
OFF
OFF
OFF
Restart system.
If the problem persists,
send module to
EUCHNER for repair.
Error in another
expansion module or
MSC-CB
OFF
ON
OFF
OFF
OFF
Restart system.
Check which module is
in the ERROR mode.
Expansion module of
the same type with
the same address de-
tected
OFF
Flashes 5
times
Flashes 5
times
OFF
OFF
Change address of the
module (see
NODE_SEL)
External feedback
loop error relay cate-
gory 4
ON
OFF
Flashes 4
times
Flashes 4 times
(only the LED corre-
sponding to the output
in the ERROR mode)
Check terminal 5, 6, 7,
8.
Internal node
detection error
OFF
Flashes 3
times
OFF
Flashes 3 times
OFF
OFF
Send module to
EUCHNER for repair
Table 42 Troubleshooting AZ-FO4