TIMER OPERATORS (max. number = 16)
Using the operators of type TIMER a signal (TRUE or FALSE) can be generated for a user-
defined time.
CLOCKING
Using the CLOCKING operator a clock signal
output with the required duration is gener-
ated if the input is "1" (TRUE).
The parameters
Time: The time can be set to a value be-
tween 10 ms and 1098.3 s.
MONOSTABLE
Using the MONOSTABLE operator an output of
"1" (TRUE) is generated by the rising edge on the
input. This state is retained for the time set.
The parameters
Time: The time can be set to a value between 10
ms and 1098.3 s.
Leading Edge: If selected, the output is set to "1" (TRUE) by a rising edge on the input
signal and remains in this state for the time set. This state can be extended as long as
the input remains at "1" (TRUE).