SPM0, SPM1, SPM2 (Figure 27)
Indicates the
physical ad-
dress of the
module
• Send module to
EUCHNER for repair
• Firmware version not
compatible with
MSC-CB. Send to
EUCHNER for firm-
ware upgrade.
• Replace Encoder
• Send to EUCHNER for
repair
Internal proximity
switch fault
• Replace proximity
switch
• Send to EUCHNER for
repair
Internal node
detection error
• Send module to
EUCHNER for repair
Expansion module
of the same type
with the same ad-
dress detected
• Change address of
the module
(see NODE_SEL)
Encoder not con-
nected, but request-
ed by configuration
• Check connection
and power supply for
the Encod-
er/proximity switch
• Check input fre-
quency (in range)
Proximity switch not
connected, but re-
quested by configu-
ration
Table 44 – Troubleshooting SPM1/SPM2
* IF SPM0 MODULE NOT FITTED
** IF ERROR ON A SINGLE CHANNEL, THE FOLLOWING ERROR INFORMATION IS INDICATED IN SUCCESSION:
FIRST THE ERROR, THEN THE ERRONEOUS CHANNEL.