CHAPTER 96
PAGE 7
MAINTENANCE MANUAL EXTRA 330LX
PAGE DATE: 1. March 2011
96-20-00 DISTRIBUTION
Refer to figure 1. The same pump (2) which is used for
refilling the tanks (normal polarity) injects the smoke oil
from the smoke oil tanks through an overpressure/check
valve (3) and the injector nozzle (8) into the hot exhaust gas
to generate smoke. The pump is controlled by the SMOKE
switches (11, 12) and the relais (15). The smoke system is
electrically protected by the SMOKE SYSTEM circuit
breaker (14).
For smoke system activation the SMOKE ARM switch (12)
has to be switched to the ON-position. Then the smoke ON-
OFF toggle switch (13) can be used to control the smoke.