A1000 90 532210 04 - Rev.A
Translation of the original instructions
ENGLISH
Defines the automations behaviour with emergency battery, in case
of mains power outage. Available options are:
1. FUNCTION
- Disabled
- Until the last movement
- Now last motion
2. LAST MOVEMENT
- Opening
- Closing
3. NIGHT-TIME FUNCTION
- Now last motion
- Until the last movement
4. LAST MOVEMENT NIGHT
- Closing
- Opening
If the door is in NIGHT-TIME, battery operation is not active.
Default CF1 CF2 CF2 CF4 CF5
FUNCTION Disabled ---
LAST MOVEMENT Opening
NIGHT-TIME FUNCTION Until the last movement
LAST MOVEMENT NIGHT Closing
6 MOTOR BLOCK KIT
OK
OK
MOTOR BLOCK KIT
2
PROGRAMMING
Defines the motor block behaviour
(OPTIONAL accessory)
Options:
- 1 LOCK TYPE
- 2 FUNCTION
- 3 MONITORING KIT
- 4 BATTERY OPERATION
1 LOCK TYPE
Defines the type of motor block:
- XB LOCK
- XM LOCK
2 FUNCTION
Defines operating methods in which motor block is activated;
- Disabled
- Night
- Night + Open
- Night-time and One-directional
- Always
3 MONITORING KIT
Enables/disables monitoring on motor block;
- ENABLED
- DISABLED
If the monitoring kit (OPTIONAL accessory) is not installed, disable.
4 BATTERY OPERATION
Defines battery operation of the motor block:
- STANDARD: the mode of operation selected is kept even with
battery operation.
- NIGHT: motor block active only in NIGHT-TIME mode.
- ALWAYS OPEN: motor block active in OPEN mode
* the REVERSE parameter determines the reverse speed of the leaf during
closing with a 5-level setting from 1 (slow) to 5 ( fast).
Default CF1 CF2 CF2 CF4 CF5
SPEED 5 5 5 5 ---
SLOWDOWN 1 1 1 1 ---
SLOWDOWN SPEED 1 1 1 1 ---
FORCE 5 5 5 5 ---
FORCE TIME 1.0 1.0 2.0 1.0 ---
ACCELERATION 8 8 5 8 ---
DECELERATION 6 6 6 4 ---
REVERSE 5 5 5 5 - --
MOVEMENT DAMPING
Select and modify the parameter from the list:
- MOVEMENT DAMPING (*) 1-5
* the MOVEMENT DAMPING parameter enables the deceleration
ramp to be programmed in the event of a stop or a reverse movement.
Default CF1 CF2 CF2 CF4 CF5
MOVEMENT DAMP. 5 5 5 5 ----
STOP OPEN
Select and modify the parameter from the list:
- STOP OPEN (*) 0-10
* the STOP OPEN parameter allows you to program the motor to stop in
advance in correspondence to the passage opening.
Default CF1 CF2 CF2 CF4 CF5
STOP OPEN 5 5 5 5 ----
3 TIMING
OK
OK
TIMING
2
PROGRAMMING
Select and modify the parameter from the list:
- 1 PAUSE TIME 0-30s
- 2 NIGHT PAUSE TIME 0-240s
- 3 NIGHT SENSOR DELAY 0-240S
Default CF1 CF2 CF2 CF4 CF5
PAUSE TIME 2 2 2 2 --
NIGHT PAUSE TIME 10 10 10 10 --
NIGHT PAUSE TIME DELAY 10 10 10 10 --
4 ENERGY SAVING
OK
OK
ENERGY SAVING
2
PROGRAMMING
The Energy Saving is disabled by default CF1,CF2. Available options are:
- ENABLED
- DISABLED
Default CF1 CF2 CF2 CF4 CF5
Energy Saving Disabled
5 BATTERY KIT
OK
OK
BATTERY KIT
2
PROGRAMMING