Certify Fiber Cabling
Settings for Fiber Tests
155
Total Connections: Enter the total number of connections that
are in each path of the link. Do not adjust the number for the
Reference Method you use. For example, if the link has 3
connections, enter “3” even if you use the 2 or 3 Jumper
reference method. When the tester calculates the loss limit, it
automatically removes the losses of the connections you used
to set the reference.
Note
For links with MPO modules, each module is one
connector.
Splices: Enter the number of splices that are in each path of
the link.
Jumper Reference: Enter the number of jumpers you will use
in each fiber path when you set the reference. The dotted
lines in the diagram on the screen show you which parts of
the link are included in the test results. See Reference Method
on page 152.
The dotted lines show you which parts of the link are included
in the test results.
Connector icons show the connections between the ends of
the link. If you enter 7 or more for the Total Connections
setting, a number inside of a connector icon shows the
number of connectors between the ends of the link. For
example, if the Total Connections setting is 7, a connector
icon shows the number 5 ( )
The round icon shows the number of splices in each path of
the link.
To see help for the screen, tap .
To save your settings, tap DONE.