EasyManua.ls Logo

Fuji Electric FRENIC-VG Series - Page 169

Fuji Electric FRENIC-VG Series
346 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.5 SX Bus Interface Card
6-93
Chap. 6
CONTROL OPTIONS
(MSB) (LSB)
15 14 10
%IW***0 Speed setting 4/Frequency command monitor
%IW***1 Torque command 2
%IW***2 Torque current command (final)
%IW***3 Magnetic flux command (final)
%IW***4 Actual speed (detected)
%IW***5 Control data (CW) (Standard DIOA, 16 bits)
%IW***6 Operation status (SW)
%IW***7 Speed setting 1/Frequency command (for V/f)
%IW***8 Line speed input
%IW***9 Pulse train position command (PG (PR))
%IW***10 Position detection (internal or PG (PD))
%IW***11 Position detection (PG (PD) Z-phase input)
%IW***12 Position command
%IW***13 VG DI (DIOB option: 16 bits)
%IW***14 FRENIC-VG Ai (Ai1)
%IW***15 FRENIC-VG Ai (Ai2)
%IW***16 VG Ai (AIO/AI option, Ai3)
%IW***17 VG Ai (AIO/AI option, Ai4)
%IW***18 Polling function code 1 address
%IW***19 Polling function code 1 data
%IW***20 Polling function code 2 address
%IW***21 Polling function code 2 data
Note: *** represents the SX bus station address set by "RSW1" and "RSW2".
Figure 6.5.20
FRENIC-VG
MICREX-SX

Table of Contents

Related product manuals