6.5    SX Bus Interface Card 
6-95 
Chap. 6 
CONTROL OPTIONS 
(3) Monitoring format 
  When the monitoring format is selected (U11=2)
, as shown in the figure below, out of the I/Q area 
of the MICREX-SX, 16 words are used for each FRENIC-VG, with the lower 4 words are used for 
read and upper 12 words are used for write. 
(MICREX-SX ← FRENIC-VG) data
(12 words)
(MICREX-SX → FRENIC-VG) data
(4 words)
(MSB) (LSB)
15 14 ・・・ ・・・ 1 0
~
~
~
~
~
~
~
~
16 words
MICREX-SX
I/Q area
 
Figure 6.5.22 
 
 (MSB)  (LSB)
  15 14 …              8  7                     …10
%IW***.0  Polling function code (1)  Polling function code (2) 
%IW***.1  Polling function code (3)  Polling function code (4) 
%IW***.2  Polling function code (5)  Polling function code (6) 
%IW***.3  Polling function code (7)  Polling function code (8) 
%IW***.4  Polling function code (1) data 
%IW***.5  Polling function code (2) data 
%IW***.6  Polling function code (3) data 
%IW***.7  Polling function code (4) data 
%IW***.8  Polling function code (5) data 
%IW***.9  Polling function code (6) data 
%IW***.10  Polling function code (7) data 
%IW***.11  Polling function code (8) data 
%QW***.12  Polling function code (1)  Polling function code (2) 
%QW***.13  Polling function code (3)  Polling function code (4) 
%QW***.14  Polling function code (5)  Polling function code (6) 
%QW***.15  Polling function code (7)  Polling function code (8) 
 
Note: *** represents the SX bus station address set by "RSW1" and "RSW2". 
Figure 6.5.23 
FRENIC-VG
⇓ 
MICREX-SX
MICREX-SX
⇓ 
FRENIC-VG