P a g e | 186
UCM6200 Series User Manual
Figure 115: Inbound Route - Multiple Mode
When Multiple Mode is enabled for the inbound route, the user can configure a “Default Destination” and a “Mode
1” destination for this route. By default, the call coming into this inbound route will be routed to the default
destination.
SIP end devices that have registered on the UCM6200 can dial feature code *62 to switch to inbound route
“Mode 1” and dial feature code *61 to switch back to “Default Destination”. Switching between different mode
can be easily done without Web GUI login.
For example, the customer service hotline destination has to be set to a different IVR after 7PM. The user can
dial *62 to switch to “Mode 1” with that IVR set as the destination before off work.
To customize feature codes for “Default Mode” and Mode 1”, click on under
“Inbound Routes” page, check “Enable Inbound Multiple Mode” option and change “Inbound Default Mode” and
“Inbound Mode 1” values (By default, *61 and *62 respectively).

Table of Contents

Other manuals for Grandstream Networks UCM6204

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grandstream Networks UCM6204 and is the answer not in the manual?

Grandstream Networks UCM6204 Specifications

General IconGeneral
BrandGrandstream Networks
ModelUCM6204
CategoryPBX
LanguageEnglish

Related product manuals