• Local UCM Server
Once selected, click on the Server Path field to upload the phonebook XML
file. Please note: after uploading the phonebook XML file to the server, the
original file name will be used as the directory name and the file will be
renamed as phonebook.xml under that directory.
Configure the phonebook download interval (in Minute). If set to 0, automatic
download will be disabled. Valid range is 5 to 720.
If set to "Yes", when XML phonebook is downloaded, the entries added
manually will be automatically removed.
Firmware source via ZeroConfig provisioning could a URL for external server
address, local UCM directory or USB media if plugged in to the UCM6200.
Select a source to get the firmware file:
• URL
If select to use URL to upgrade, complete the configuration for the following
four parameters: “Upgrade Via”, “Server Path”, “File Prefix” and “File
Postfix”.
• Local UCM Server
Firmware can be uploaded to the UCM6200 internal storage for firmware
upgrade. If selected, click on “Manage Storage” icon next to “Directory”
option, upload firmware file and select directory for the end device to
retrieve the firmware file.
• Local USB Media
If selected, the USB storage device needs to be plugged into the UCM6200
and the firmware file must be put under a folder named “ZC_firmware” in
the USB storage root directory.
• Local SD Card Media
If selected, an SD card needs to be plugged into the UCM6200 and the
firmware file must be put under a folder named “ZC_firmware” in the USB
storage root directory.