172
Table 249 Pinouts of DSIC-1SHDSL-8W interface module cable
Pin
Line
Signal
1
1
Ring
2
1
Tip
3
2
Ring
4
0
Ring
5
0
Tip
6
2
Tip
7
3
Ring
8
3
Tip
Connecting a MIM-1SHL-4W interface module cable
One end of the cable provides one RJ11 connector, the other end of the cable provides two RJ11
connectors that can be connected to two 2-core telephone cables.
To connect the 4-wire Y type G.SHDSL interface cable:
1. Connect the end with only one RJ11 connector of the cable to RJ11 interface on the
MIM-1SHL-4W interface module
2. Connect the other end of the cable to the network device.
Connect the 4-wire I type G.SHDSL interface cable as follows:
Each end of the cable provides one RJ11 connector that can be connected to one 4-core telephone
cable.
1. Connect one end of the cable to the RJ11 interface on the MIM-1SHL-4W interface module.
2. Connect the other end of the cable to the network device.
Use correct wire pairs when the MIM-1SHL-4W interface module cable is operating in different
modes:
When the interface module cable is operating in dual-wire mode, use Line 0.
When the interface module cable is operating in four-wire mode, use Line 0 and Line 1.
Table 250 Pinouts of the MIM-1SHL-4W interface module cable
Pin
Line
Signal
1 1 Tip
2 0 Tip
3 0 Ring
4 1 Ring

Table of Contents