Device
Error
Code
Description
("
Device
__
c'
Error
Address
Subdevice
xx
y
Address
zz
5103 Printer
057 5
00
Missing print emitter pulses - A print emitter pulse was not found
(continued) during the specified time (150
ms
-
SO
cps, 100 ms - 120 cps).
(
The print head stepper
motor
begins turning when
it
receives
pulses from the printer adapter. Error checking begins when the
print head stepper motor is up
to
speed.
If
a print emitter pulse
does not occur during the 100 ms or 150 ms timing, a 057 error
occurs.
If
a print emitter pulse does occur but is
not
the expected
(
pulse, a 056 error occurs. Refer
to
Print Emitter Error Timing
following these error codes.
Failures that prevent the carrier from moving (broken belt) cause a
057 error. Light mechanical binds or print emitter failure usually
cause a 056 error.
058 5
00
Timer interrupt
time-out
- Defective
1.1
ms or 2.66 ms (120 cps)
timer
or
1.1
ms
or
3.3 ms
(SO
cps) timer. Timer accuracy is
checked by running the printer diagnostic program (MOl 800).
059 5
00
Overspeed error -
Five
or
six print emitters occurred during one
print head stepper motor step. Normal number
of
print emitters is
2
to
4 per motor step.
Tape
900
to
E
xx
Diagnostic errors generated by diagnostic sections. Refer
to
,
999 Diagnostic Program Routines or
MAP
300
for
error definitions.
\{
Diagnostic Program Routines 3-63

Table of Contents

Other manuals for IBM 5100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 5100 and is the answer not in the manual?

IBM 5100 Specifications

General IconGeneral
Release Year1975
RAM16 KB - 64 KB
Storage204 KB tape drive
Display5-inch CRT
Operating SystemAPL/BASIC
ProcessorIBM PALM (1.9 MHz)

Related product manuals