EasyManua.ls Logo

IBM 5100 - Serial IO Error Codes

IBM 5100
389 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERIAL
I/O
ERROR
CODES
The display format
for
serial
I/O
error codes is:
ERROR
xxx yyy
where xxx
is
the error code and yyy is the device
address
of
the failing device.
Device
Error Codes
Error Device Address
510 002
yyy
003
yyy
3-64
Description
An invalid command was sent
to
an
I/O
device. For example:
A REWIND (BASIC) or )REWIND (APL) command is issued
to
an
I/O
device.
An invalid device characteristic was specified
to
the command device.
The input buffer size was increased after the input device was opened.
An invalid parameter was specified when opening the command device
or
an
I/O
device.
In modem mode, a data terminal ready from the
I/O
device is
off
during a
5100 transmit operation. In terminal mode, data set ready from the
I/O
device is
off
during a 5100 transmit operation. These conditions
can
be
caused by:
The
I/O
device does not conform
to
the EIA RS232C standard
interface.
A defective cable.
The
I/O
device power is not on.
The
I/O
device is attached with the wrong cable.
/