GETB
oA,
Ry,
SM
(op code E): A data byte
is
trans·
ferred from
an
I/O device designated by
oA
to
a storage
location designated by
the
storage address register (Ry).
The data byte
is
sent from the device
on
bus in. The
indirect address in
the
storage address register
is
modified
after
the
microinstruction·
is
executed.
Modifier
0 Plus 1
1 Plus 2
2 Plus 3
3
Plus 4
4 Minus 1
5
_Minus
2
6
Minus 3
7 Minus 4
8,9,A,B
No
change
C,o,E,F
This
is
the GETRB instruction
'Get strobe' and
'op
code
E'
are activated during this
microinstruction
to
signal the I/O device
that
this
is
a
GETB microinstruction.