EasyManuals Logo
Home>IBM>Server>eserver i5

IBM eserver i5 User Manual

IBM eserver i5
940 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #306 background imageLoading...
Page #306 background image
5486Towr.fm Draft Document for Review October 18, 2004
272 IBM Eserver i5 and iSeries System Handbook
#5088 PCI-X Expansion Unit schematic
#0588 PCI-X Expansion Unit in Rack
The #0588 is the equivalent of a #5088 PCI-X Expansion Unit, but the #0588 is
mounted in an #0551 or #0550 rack. A #0588 is eight EIA units high and has 14
PCI-X slots for PCI IOPs and IOAs. Disk units and removable media are not
supported by the #0588. An #0588 can be on initial, upgrade, or MES orders, but
cannot be converted to a #5088.
PCI IOAs are supported by feature #2843/#2844 PCI IOPs, feature #2790, #2890
PCI Integrated Netfinity® Servers, feature #2791, #2792, #2799, #2891, #2892,
#2899 PCI Integrated xSeries Servers, and the #4710 PCI Integrated xSeries
Server. A #9844 may be used in an #0588. It cannot be ordered with or for a
#0588.
The #0588 has two redundant 575W power supplies and two integrated Power
Distribution Units (PDU) compatible line cords. The line cords may be connected
to the same PDU or separate PDUs in the #0550 or #0551 rack. When the line
OP Panel
Multi-
Adapter
Bridge
Boundary
Multi-
Adapter
Bridge
Boundary
Back
Legend
Base Feature
Required Feature
Unavailable if
Integrated xSeries
Server is installed
Front
POWER
P01
(B01)
POWER
P02
(B02)
Note 2: If C11 has an Integrated xSeries
Server, slot C12 is unavailable, and slot C13
is available only as a short slot. A #2792 does
not reduce a third slot to a short slot.
Note 1: If C05 has an Integrated xSeries
Server, slot C06 is unavailable, and slot C07
is available only as a short slot. A #2792 does
not reduce a third slot to a short slot.
Note 3: IXS placement is not
supported from plant. Only a
#2792 is allowed in this position.
PCI Cards
Multi-Adapter Bridge
Bus Number
Slots
3 IOA
4 IOA
1,2 IOP/IOA/IXS
5,6 IOP/IOA
HSL
7,8 IOA
3,4 IOA
5,6 IOP/IOA
7,8 IOA
1,2 IOP/IOA/IXS
5,6 IOP/IOA
4 IOP/IOA
1,2 IOP/IOA/IXS
7,8 IOA
3 IOP/IOA
1
2
C07
C10
C11
C12
C13
C14
C15
C01
C02
C03
C04
C05
C06
C09
C08
3
Note: All slots are 3.3V
VPD
SPCN

Table of Contents

Other manuals for IBM eserver i5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM eserver i5 and is the answer not in the manual?

IBM eserver i5 Specifications

General IconGeneral
BrandIBM
Modeleserver i5
CategoryServer
LanguageEnglish

Related product manuals