Table 29: AC Power Cord Specifications
GraphicJuniper Model NumberPlug StandardsElectrical SpecificationsCountry/Region
CBL-EX-PWR-C13-AUAS/NZ 3109-1996250 VAC, 10 A, 50 HzAustralia
CBL-EX-PWR-C13-CHGB 1002-1996250 VAC, 10 A, 50 HzChina
CBL-EX-PWR-C13-EUCEE (7) VII250 VAC, 10 A, 50 HzEurope (except Italy,
Switzerland, and United
Kingdom)
CBL-EX-PWR-C13-ITCEI 23-16/VII250 VAC, 10 A, 50 HzItaly
CBL-EX-PWR-C13-JPJIS C8303125 VAC, 12 A, 50 Hz or 60 HzJapan
CBL-EX-PWR-C13-USCAN/CSA No. 49-92125 VAC, 13 A, 60 HzNorth America
CBL-EX-PWR-C13-KRKSC 8305; K60884-1250 VAC, 10 A, 60 HzSouth Korea
CBL-EX-PWR-C13-SZSEV 1011 SEV 1991; EN
60320 C13
250 VAC, 10 A, 50 HzSwitzerland
CBL-EX-PWR-C13-UKBS 1363/A250 VAC, 10 A, 50 HzUnited Kingdom
Related
Documentation
AC Power Supply for a QFX3500, QFX3600, or QFX3600-I Device•
• General Safety Guidelines and Warnings on page 239
• General Electrical Safety Guidelines and Warnings on page 261
• Prevention of Electrostatic Discharge Damage on page 263
• AC Power Supply for a QFX5100 Device on page 47
• QFX10002 AC Power Specifications
• QFX5200 AC Power Specifications
• QFX5110 AC Power Specifications
DC Power Specifications for a QFX5100 Device
Table 30 on page 82 describes the DC power specifications for DC product SKUs of the
QFX5100 device.
81Copyright © 2016, Juniper Networks, Inc.
Chapter 7: Power Specifications and Requirements