Table 3: QFX5100 Switch Product Numbers (continued)
Airflow
Number
of Mgt.
Ports
Power
Supply
Number of
Expansion
ModulesPortsP roduct Numbers
Air Out (ports to
FRUs)
3DC48 10GBASE-T and 6
QSFP+ transceivers
QFX5100-48T-DC-AFO
Air In
(FRUs-to-ports)
2AC96 SFP+ and 8 QSFP+
transceivers
QFX5100-96S-AFI
Air Out
(ports-to-FRUs)
2AC96 SFP+ and 8 QSFP+
transceivers
QFX5100-96S-AFO
Air In
(FRUs-to-ports)
2DC96 SFP+ and 8 QSFP+
transceivers
QFX5100-96S-DC-AFI
Air Out
(ports-to-FRUs)
2DC96 SFP+ and 8 QSFP+
transceivers
QFX5100-96S-DC-AFO
CAUTION: Mixing different types (AC and DC) of power supplies in the same
chassisis not supported.Mixing different airflow modules in the same chassis
is not supported.
Related
Documentation
Management Panel of a QFX5100 Device on page 19•
• Port Panel of a QFX5100-48S Device on page 28
• Port Panel of a QFX5100-24Q Device on page 23
• Port Panel of a QFX5100-96S Device on page 32
• QFX5100 Device Hardware Overview on page 3
Field-Replaceable Units in a QFX5100 Device
Field-replaceable units (FRUs) are components that you can replace at your site. The
QFX5100 device FRUs are hot-insertable and hot-removable: you can remove and replace
one of them without powering off the switch or disrupting the switching function.
CAUTION: Replace a failed power supply with a blank panel or new power
supply within one minute of removal to prevent chassis overheating. The
switch continues to operate with only one power supply running. Replace a
failed fan module with a new fan module within one minute of removal to
prevent chassis overheating. Do not operate the switch with missing FRUs
for longer than one minute.
Copyright © 2016, Juniper Networks, Inc.12
QFX5100 Switch Hardware Guide