chassis, which is visible through the mounting bracket.
3. Secure the grounding lug to the protective earthing terminal with the washers and
screws. See Figure 54 on page 171 and Figure 55 on page 171.
Figure 54: Connecting a Grounding Cable to a 1 U QFX5100 Device
Figure 55: Connecting a Grounding Cable to the 2 U QFX5100-96S Device
48
49
0
1
2
3
4
5
6
7
8
9
10
11
50
51
52
53
54
55
56
57
58
59
4. Dress the grounding cable and ensure that it does not touch or block access to other
device components and that it does not drape where people could trip over it.
Related
Documentation
General Safety Guidelines and Warnings on page 239•
• Grounded Equipment Warning on page 255
• Connecting AC Power to a QFX5100 Device on page 171
• Connecting DC Power to a QFX5100 Device on page 174
Connecting AC Power to a QFX5100 Device
The QFX5100 is shipped from the factory with two power supplies. Each power supply
is a hot-removable and hot-insertable field-replaceable unit (FRU) when the second
power supply is installed and running. You can install replacement power supplies in the
two slots next to the fan modules without powering off the switch or disrupting the
switching function.
Ensure that you have a power cord appropriate for your geographical location available
to connect AC power to the switch.
Before you begin connecting AC power to the switch:
171Copyright © 2016, Juniper Networks, Inc.
Chapter 12: Connecting the Switch to Power