Figure 56: Connecting an AC Power Cord to an AC Power Supply in a 1 U
QFX5100 Device
1— Power cord retainer
Figure 57: Connecting an AC Power Cord to an AC Power Supply in a 2 U
QFX5100 Device
6. If the AC power source outlet has a power switch, set it to the OFF (O) position.
NOTE: The switch powers on as soon as power is provided to the power
supply. There is no power switch on the device.
7. Insert the power cord plug into an AC power source outlet.
8. If the AC power source outlet has a power switch, set it to the ON (|) position.
9. Verify that the AC and DC LEDs on each power supply are lit green.
If the amber fault LED is lit, remove power from the power supply, and replace the
power supply (see “Removing a Power Supply from a QFX5100 Device” on page 204
). Do not remove the power supply until you have a replacement power supply ready:
the power supplies or a blank cover panel must be installed in the switch to ensure
proper airflow.
CAUTION: Replacea failed power supply with a blankpanel or new power
supply within 1 minute of removal to prevent chassis overheating.