[SENSe:]VOLTage:AC:RANGe:AUTO <b>
This command turns autorange on or off for AC voltage measurements.
Parameters
<b> description
0 or OFF
Turn autorange off.
1 or ON
Turn autorange on.
Query
command description
[SENSe:]VOLTage:AC:RANGe:AUTO?
Query AC voltage autorange state.
[SENSe:]VOLTage:AC:RESolution <n>|MIN|MAX
Use this command to select resolution for AC voltage measurements (ACV).
Parameters
<n> description
(1.00e-06 to 1.00e-04) * ACV range
Select the resolution of the measurement.
MINimum
Select the minimum value.
MAXimum
Select the maximum value.
Query
command description
[SENSe:]VOLTage:AC:RESolution?
Query the measurement resolution.
[SENSe:]VOLTage:AC:RESolution? MIN
Query the minimum resolution.
[SENSe:]VOLTage:AC:RESolution? MAX
Query the maximum resolution.
Details
Refer to Bandwidth and resolution for AC measurements (on page 3-44) more information about resolution.

Table of Contents

Other manuals for Keithley 2110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2110 and is the answer not in the manual?

Keithley 2110 Specifications

General IconGeneral
BrandKeithley
Model2110
CategoryMultimeter
LanguageEnglish

Related product manuals